Fan-Filter-Unit

BECKER fan filter units produce a clean environment where you need it. The ambient air is suctioned through a pre-filter (optional) by the fan unit, and then flows through a HEPA or ULPA filter to the clean-room side.

 

FFM type

The modules with plastic housing are suitable for installation in standard T-profile clean-room ceilings. The unique design allows you a large selection of accessories so that you can fulfil your individual requirements.

 

 

 

Cleanness Class

Class 5 acc. to DIN EN ISO 14644-1 (Class 100 acc. to former US Fed. Std.209)

 

Fan unit

Maintenance-free ball bearing (approx. 140,000 h service life)

Flange motor with fan air intake at one side

 

Pre-filter

Washable filter, filtration efficiency 40 %eff. 
(ASHRAE STD 52-68)

 

Filter standard

HEPA filter 99.99%eff. for 0.3 µm and larger

 

Motor / control

230V / 50 Hz / 0.9 A speed control via potentiometer on the unit inc. connection lead for circuit-entering at terminal boxes, connector optionally available according to US Federal Standards 209 guidelines and the VDI specification 2083.

 

Acceptance

Every filter is subjected to a leak test with photometer and aerosol generator before dispatch

and given a certificate

 

 

Special versions

optionally available

 

Filter

ULPA filter 99.9995% eff. for 0.12 µm and larger

 

Motor / control

Master controller for group circuitry

 

RSR type

The modules are suitable for installation in standard T-profile clean-room ceilings.
Room-side replaceable modules allow access to the filters and to the fan unit from the room-side.

 

 

 

Cleanness Class

Class 100 with HEPA filter

 

Fan unit

Maintenance-free ball bearing (approx. 140,000 h service life)

Flange motor with fan air intake at one side

 

Filter standard

HEPA filter 99.99%eff. for 0.3 µm and larger

 

Motor / control

230V / 50 Hz / 0.9 A speed control via potentiometer on the unit inc. connection lead for circuit-entering at terminal boxes, connector optionally available according to US Federal Standards 209 guidelines and the VDI specification 2083.

 

Acceptance

According to US Federal Standards 209 guidelines and VDI specification 2083.

Every device is subjected to a leak test with photometer and aerosol generator before dispatch and given a certificate.

 

 

Special versions

Optionally available

 

Filter

ULPA filter 99.9995% eff. for 0.12 µm and larger

 

Pre-filter

 

Housing attachment with washable filter 40% eff.

(ASPHRAE STD 52-68)

 

Size

Type 22: 600 x 600 x 318 mm (LxWxH)

 

Motor

400 V / 50 Hz or 115 V / 60 Hz

 

Control

Master controller for group circuitry